Category

Earthing & Bonding

42 articles · Referenced to BS 7671 · Free

What is Neutral/Earthing?

Earthing and bonding are two of the most fundamental safety features of your home's electrical system. Earthing provides a safe path for fault current so circuit breakers trip quickly. If you get a tingle or shock from metal taps, pipes, or appliances, this is a serious warning sign — call an electrician immediately.

What you'll find here

✓

What earthing is and why it matters

✓

Why you might get a shock from a tap or pipe

✓

Main protective bonding requirements

✓

TN-S, TN-C-S (PME), and TT earthing systems

✓

Supplementary bonding in bathrooms

✓

Earthing for EV chargers and outbuildings

⚠️

Safety note: A shock from metal pipework or appliances is a serious electrical emergency. Switch off at the main switch and call an emergency electrician immediately.

42 articles in Neutral/Earthing

Basics

1 question

What is earthing in a house and why does it matter?

Earthing provides a safe path for fault current so that protective devices trip quickly if something goes wrong. Without proper earthing, a fault could make your appliances dangerously live.

Read answer →

Earth Faults

2 questions

Why is my earth wire carrying voltage when the main switch is turned off?

An earth wire carrying voltage with the main switch off usually means current is back-feeding through a neutral-to-earth fault, a cross-connection between circuits, or leakage from a neighbouring supply. Switch everything off and do not touch exposed metalwork. This situation is dangerous and must be investigated by a qualified electrician using an insulation resistance test and loop impedance measurements before the installation is used again.

Read answer →

Why does my earth wire carry voltage when the main switch is off?

An earth wire carrying voltage with the main switch off almost always points to a neutral-to-earth fault, a borrowed neutral from a neighbouring circuit, or backfeed from a shared supply before your isolator. First, do not assume the installation is safe — treat any live earth as a serious fault. Switch off at the consumer unit, avoid touching exposed metalwork, and call a Part P registered electrician immediately. This condition can make normally safe metalwork dangerously live and may indicate a fault that your RCD cannot detect reliably.

Read answer →

Earth Systems

1 question

What is PME earthing failure and why is it dangerous?

PME earthing failure occurs when the combined protective earth and neutral (PEN) conductor in a TN-C-S supply system loses continuity, causing exposed metalwork in your home to rise to a dangerous voltage. The most common cause is a broken or corroded neutral conductor in the distributor's network. If you suspect a PME fault, do not touch any metalwork and call your Distribution Network Operator immediately. This is a life-threatening emergency, not a DIY repair.

Read answer →

Earthing Faults

1 question

Why does my earth wire get warm?

A warm earth wire means current is flowing through it, which should not happen under normal conditions — it indicates a wiring fault or a neutral-earth connection problem that needs immediate investigation.

Read answer →

Earthing Systems

4 questions

What is PME earthing failure and why is it dangerous for my home?

PME earthing failure occurs when the combined neutral and earth conductor (PEN conductor) on a TN-C-S supply loses continuity, causing the earth in your home to rise to a dangerous voltage instead of remaining at zero volts. The most common cause is a broken or corroded neutral connection between the transformer and your property. If you suspect a PME failure, do not touch metalwork in your home and call your Distribution Network Operator immediately. This is a life-threatening emergency, not a job for a homeowner or standard electrician to investigate alone.

Read answer →

What is PME earthing failure and why is it so dangerous?

PME earthing failure occurs when the combined PEN conductor (neutral and earth) in a TN-C-S system loses its connection to the supply network earth, causing the installation earth to rise to a dangerous voltage rather than remaining at zero volts. The most common cause is a broken or corroded neutral conductor upstream of the property. If you suspect a PME fault, do not touch metalwork in the property and call your Distribution Network Operator immediately. This is a life-threatening situation requiring urgent professional action.

Read answer →

What is PME earthing failure and why is it so dangerous for my home?

PME earthing failure occurs when the combined neutral-earth conductor in a TN-C-S supply system loses connection, causing exposed metalwork in your home to become live at mains voltage. The most common cause is a broken or corroded PEN conductor in the distributor's network. If you suspect a PME fault, do not touch any metalwork and call your District Network Operator immediately. This is one of the most dangerous electrical faults possible and requires urgent professional attention.

Read answer →

What is the difference between TN-S, TN-C-S, and TT earthing systems?

TN-S has separate neutral and earth conductors from the supply. TN-C-S (PME) combines them in one conductor back to the substation. TT uses a local earth electrode instead of a supply earth.

Read answer →

Fault Condition

1 question

Why is my neutral wire at the fuse box glowing red when nothing is switched on?

A neutral wire glowing red at the fuse box is a serious warning sign, most commonly caused by a loose or corroded neutral connection creating high resistance and heat. This can also indicate an overloaded neutral conductor or a lost neutral from the supply. Turn off your main switch immediately and do not restore power until a qualified electrician has inspected the installation. This is a fire and electrocution risk. Do not touch the wire or attempt any investigation yourself.

Read answer →

Fault Finding

3 questions

What is a floating neutral and how do I fix it?

A floating neutral occurs when the neutral conductor loses its connection to earth reference, causing unpredictable and dangerous voltages across circuits. The most common cause is a broken or disconnected neutral at the consumer unit, meter tails, or supplier's cutout. Switch off at the main switch immediately if you suspect this fault, as voltages can rise dangerously on one phase. Do not attempt to investigate further yourself — this is a Category C1 emergency requiring a qualified electrician or your DNO if the fault is upstream of the meter.

Read answer →

Why do I have voltage on my earth conductor?

Voltage on an earth conductor usually indicates a lost or high-resistance neutral (N-E voltage rise), a wiring fault such as neutral-earth reversal or cross-connection, or leakage current from connected equipment. Measure the voltage: under 10V AC at low load is often normal N-E rise on a long run; anything above that, or any DC voltage, needs investigation. Do not ignore it — a live earth is a serious shock and fire risk. Switch off affected circuits and call a qualified electrician immediately if you are unsure.

Read answer →

Why is my neutral conductor overheating in the fusebox?

A neutral conductor overheating in your fusebox is most commonly caused by a loose or corroded terminal connection creating resistance, or by sustained overcurrent from an overloaded circuit. Less commonly, it may indicate neutral-earth reversal or a lost neutral on a shared neutral (multi-wire) system. Switch off the affected circuit immediately and do not use it. This fault poses a serious fire and electric shock risk — contact a registered electrician (NICEIC/NAPIT) without delay.

Read answer →

Fault Types

1 question

What is a split neutral fault and why did it cause all my appliances to fail?

A split neutral fault occurs when the neutral conductor in your supply or consumer unit loses continuity, causing voltage to become unbalanced across your circuits. The most common cause is a loose or corroded neutral connection at the meter tails, consumer unit, or distribution network. All appliances can fail simultaneously because without a stable neutral reference, voltages on live conductors can rise dangerously above 230V or collapse entirely. Switch off your main breaker immediately and call a qualified electrician or your DNO. Do not attempt to investigate the supply side yourself.

Read answer →

Faults

5 questions

Why does my circuit have continuity between neutral and earth when nothing is plugged in?

Continuity between neutral and earth when nothing is plugged in is normal on a TN-S or TN-C-S (PME) supply where neutral and earth are bonded at the origin of the installation. On a correctly wired circuit you should see a low resistance reading, typically under 1 ohm, at the consumer unit end. If the reading appears on a socket circuit mid-run with no appliances connected, suspect a wiring fault, crossed conductors, or a damaged neutral conductor touching an earthed enclosure. Have a qualified electrician investigate before using the circuit.

Read answer →

Why does my circuit show continuity between neutral and earth when nothing is plugged in?

Continuity between neutral and earth with nothing plugged in is normal on a TN-C-S (PME) supply, where neutral and earth are bonded at the meter or consumer unit. On a TT system it may indicate a wiring fault. Check whether your supply is PME first. If readings are unexpected or you have any doubt, stop testing and call a qualified electrician, as faults in this area affect shock protection for the whole installation.

Read answer →

What is a split neutral fault and can it cause a house fire?

A split neutral fault occurs when the neutral conductor is broken or has high resistance between two points in a circuit, causing voltage imbalance and potentially dangerous overvoltages on connected appliances. It is most commonly caused by a loose neutral connection at the consumer unit, a corroded neutral bar, or damaged neutral wiring. Yes, it can cause a house fire through arcing at the fault point or overheating of appliances running on incorrect voltages. If you suspect a split neutral, switch off at the main switch and call a qualified electrician immediately.

Read answer →

Why do I have no earth on my socket?

A missing earth on a socket is most commonly caused by a disconnected or broken earth wire at the socket, consumer unit, or junction point. It can also result from old two-core wiring (pre-1960s installations lack an earth conductor entirely). Do not use the socket until the fault is investigated — an unearthed socket is a serious electric shock and fire risk. Have a qualified electrician inspect and test the circuit immediately.

Read answer →

Why is my neutral wire overheating?

A neutral wire overheats most commonly due to a loose or corroded connection creating high resistance at a terminal, junction, or consumer unit. It can also result from overloading, a broken neutral causing current imbalance in three-phase systems, or undersized conductors. Turn off the affected circuit at the consumer unit immediately and do not restore power until a qualified electrician has inspected and repaired the fault. An overheating neutral is a serious fire risk and must not be ignored.

Read answer →

Faults & Hazards

1 question

Why is my neutral wire at the consumer unit showing a temperature of 70°C?

A neutral wire reading 70°C at your consumer unit almost always indicates a loose or corroded neutral connection causing resistance heating. This is a serious fire and electric shock hazard. Switch off the affected circuit immediately, do not restore power until a qualified electrician has inspected and re-terminated all neutral connections. Under BS 7671 18th Edition, conductor operating temperatures must not exceed 70°C for standard PVC-insulated cables, so this reading means you are already at the absolute design limit.

Read answer →

Faults & Safety

1 question

Why is my neutral wire glowing red when the main switch is off?

A neutral wire glowing red when the main switch is off almost always indicates severe overloading, a high-resistance connection, or current back-feeding through a parallel path. The wire has been carrying excessive current, heating the insulation to dangerous levels. Switch off all circuits at the consumer unit immediately, do not restore power, and call a qualified electrician today. This is a fire and electrocution risk. Even with the main switch off, voltage may still be present on the neutral if back-feed is occurring.

Read answer →

Neutral Faults

2 questions

Why is my neutral wire at the consumer unit glowing red and getting dangerously hot?

A glowing red or dangerously hot neutral wire at your consumer unit almost always means a loose or corroded neutral connection creating high resistance at that joint. This causes the wire to heat up, which is a serious fire and electrocution risk. Turn off your main switch immediately, do not touch the wire, and call a registered electrician today. Do not restore power until a professional has inspected, tested, and repaired the fault. This is not a DIY repair.

Read answer →

What is a split neutral fault and can it really cause a house fire?

A split neutral fault occurs when the neutral conductor breaks or loses continuity between your consumer unit and the electricity supplier's neutral connection, causing voltages across your home to become dangerously unbalanced. The most common cause is a corroded, loose, or broken neutral at the service head, meter tails, or consumer unit. Yes, it can cause a house fire — overvoltage from a split neutral can overheat appliances and wiring within seconds. If lights are flickering, dimming, or brightening unexpectedly, turn off your main switch and call a qualified electrician immediately.

Read answer →

Overheating

3 questions

Why is my earth conductor at the consumer unit showing 50°C when outside temperature is 15°C?

An earth conductor at 50°C in a 15°C ambient environment is a serious warning sign. The most likely cause is a high-resistance connection at the main earthing terminal, a neutral-to-earth fault on a circuit, or sustained leakage current flowing through the protective conductor. Switch off non-essential circuits immediately and call a qualified electrician today. Do not ignore this — a warm earth conductor indicates current is flowing where it should not be, and this poses a genuine fire and electrocution risk.

Read answer →

Why does my neutral conductor at the fuse box show a temperature of 80°C?

An 80°C reading on a neutral conductor at your fuse box (consumer unit) most commonly means a loose or corroded terminal connection causing resistance heating. It can also indicate the conductor is undersized for the load it is carrying. Either cause is serious. Switch off non-essential circuits immediately and do not ignore this reading. A registered electrician should inspect and test the consumer unit as soon as possible, as sustained overheating can damage insulation, cause arcing, and start a fire.

Read answer →

Why is my neutral conductor at the fuse box showing a temperature of 80°C?

A neutral conductor at 80°C in your fuse box is a serious warning sign. The most common cause is a loose or corroded neutral connection creating resistance, which generates heat under load. Turn off non-essential circuits immediately and call a qualified electrician today — do not ignore this. Secondary causes include an overloaded neutral shared between circuits, poor-quality terminations, or a deteriorating cable. This temperature exceeds safe operating limits for standard PVC insulation rated at 70°C and presents a real fire risk.

Read answer →

Safety

1 question

Why am I getting a small electric shock from my tap or metal pipes?

This is a serious warning sign. Switch off your electrics at the consumer unit and call an electrician immediately. Do not use water or metal fixtures until it is investigated.

Read answer →

Safety Issues

2 questions

What is touch voltage and how do I prevent it?

Touch voltage is the dangerous potential difference that appears between an exposed conductive part (like a metal appliance casing) and earth when a fault occurs. The most common cause is a broken or missing protective earth conductor. To prevent it, ensure all metalwork is correctly bonded and earthed, and fit a 30mA RCD on all final circuits. If you feel a tingle from any appliance or fitting, stop using it immediately and call a qualified electrician.

Read answer →

What causes a split neutral fault and why is it dangerous?

A split neutral fault occurs when the neutral conductor becomes loose, broken, or disconnected while the live conductor remains energised. The most common cause is a corroded, loose, or poorly terminated neutral at a junction box, consumer unit, or DNO cutout. This creates a dangerous voltage imbalance that can expose metalwork to full mains voltage. Switch off the affected circuit at the consumer unit immediately and call a Part P registered electrician — do not investigate live terminals yourself.

Read answer →

System Faults

1 question

What is a PME failure and what should I do immediately?

A PME (Protective Multiple Earthing) failure occurs when the neutral conductor from the electricity distributor becomes open-circuit, causing exposed metalwork in your home to rise to a dangerous voltage. The most common cause is a broken or disconnected DNO neutral cable. Immediately switch off your main incomer, do not touch any metalwork or appliances, and call your electricity distributor (e.g. National Grid, Western Power) on their emergency line. Do not attempt any investigation yourself — this is a life-threatening network fault.

Read answer →

Temperature

1 question

Why is my earth conductor at the consumer unit showing 40°C when outside is cold?

An earth conductor at 40°C when ambient temperatures are cold almost always means current is flowing through the earth path where it should not be. The most common cause is a neutral-to-earth fault somewhere in your installation, creating a parallel return path through the protective conductor. Switch off non-essential circuits and call a registered electrician immediately. Do not ignore a warm earth conductor — it indicates a fault that could cause electric shock, fire, or damage to equipment.

Read answer →

Temperature Issues

1 question

Why is my earth conductor at the consumer unit showing 50°C when outside is 15°C?

An earth conductor at 50°C when ambient is 15°C indicates abnormal current flow through the protective earth path. The most common cause is a wiring fault creating a parallel return path through the earth conductor, or a neutral-to-earth fault upstream. Turn off non-essential circuits immediately and call a qualified electrician today. Do not ignore this — sustained heat on an earth conductor can indicate a serious installation fault and a potential fire or electric shock risk.

Read answer →

Testing & Diagnosis

1 question

Why is there continuity between my neutral and earth when nothing is plugged in?

Continuity between neutral and earth with nothing plugged in is normal in most UK installations. At the main distribution board, the neutral and earth conductors are bonded together at a single point called the main earthing terminal. This is required by BS 7671. If you are measuring low resistance rather than a dead short, this is almost certainly that intentional connection. However, if readings appear on a socket circuit with the board isolated, investigate further or call a qualified electrician.

Read answer →

Thermal Issue

1 question

Why is my earth conductor at the consumer unit showing 40°C when it's cold outside?

A warm earth conductor at your consumer unit almost always means current is flowing through it, which should not happen under normal conditions. The most common cause is a neutral-to-earth fault somewhere in the installation, or a shared neutral on a shared supply. Switch off non-essential circuits and call a qualified electrician immediately. A warm or hot earth conductor is a fire and shock risk and must not be ignored.

Read answer →

Understanding

1 question

What is the difference between neutral and earth?

In a UK electrical installation, the neutral conductor completes the circuit by carrying current back to the source, while the earth conductor is a safety conductor that only carries current during a fault. Neutral is connected to the supply neutral at the transformer; earth is connected to the main earthing terminal and ultimately the ground. Never swap or join them — doing so creates a dangerous situation. If you're unsure about your wiring, call a qualified electrician immediately.

Read answer →

Understanding Earthing

1 question

What is the difference between neutral and earth?

Neutral is the return path for normal operating current. Earth is a safety conductor that carries current only when there's a fault — it protects you from electric shock.

Read answer →

Voltage Issues

4 questions

Why does my neutral wire show voltage to earth even when the main switch is off?

A neutral wire showing voltage to earth when the main switch is off usually means voltage is back-feeding from a neighbouring circuit, a shared neutral, or a faulty RCD. The neutral conductor in a UK TN-C-S or TN-S system should sit close to 0V relative to earth. If yours reads anything above about 2V, you need a registered electrician to investigate. Never assume a neutral is dead just because a switch is off, as neutrals can remain live under fault conditions.

Read answer →

Why does my neutral wire at the fuse box glow red when nothing is switched on?

A neutral wire glowing red in your fuse box almost always means it is carrying excessive current due to a loose connection, an overloaded circuit, or a lost neutral fault on the supply side. Heat in a neutral wire is a serious fire risk. Switch off the main switch at the consumer unit immediately, do not restore power, and call a qualified electrician today. This is not a fault you should investigate yourself as live voltages may be present even with circuits switched off.

Read answer →

Why is my earth wire carrying AC voltage when the main switch is off?

An earth wire carrying AC voltage when the main switch is off usually means current is leaking from a faulty appliance, a wiring fault creating a path between live or neutral and earth, or voltage is being back-fed from a neighbouring circuit or supply neutral problem. Switch off at the consumer unit, disconnect all appliances, and test again. If voltage remains on the earth, stop and call a qualified electrician immediately. A live earth is a serious fault that bypasses your main protection.

Read answer →

Why is my neutral wire showing 230V to earth even though nothing is switched on?

A neutral wire reading 230V to earth usually means the neutral conductor has lost its connection to earth at the supply end, often called a lost neutral or open neutral fault. This is a serious and potentially dangerous condition. The most common cause is a broken or disconnected neutral at the meter tails, distribution board, or street supply. Switch off your main breaker immediately, do not use any appliances, and call a qualified electrician or your DNO if the fault is on the supply side. Do not investigate the wiring yourself.

Read answer →

Voltage Presence

1 question

Why is my neutral wire showing voltage to earth even when the main switch is off?

A neutral wire showing voltage to earth with the main switch off almost always means the voltage is coming from a neighbouring property or the DNO supply network, not your own installation. The neutral conductor is part of a shared return path in the UK supply system and is never fully isolated by your consumer unit switch. Do not assume the circuit is safe just because your switch is off. If you are unsure, stop work and call a qualified electrician before touching any conductors.

Read answer →

Wiring Faults

1 question

What is a reversed live and neutral fault and how dangerous is it?

A reversed live and neutral fault occurs when the live (brown) and neutral (blue) conductors are connected the wrong way around at a socket, switch, or consumer unit. Most commonly caused by incorrect wiring during installation or DIY work. The appliance may still function, but the switch will be in the neutral rather than the live conductor, leaving equipment dangerously energised even when switched off. Do not ignore this fault — switch off at the consumer unit and call a qualified electrician immediately.

Read answer →
👷

ElectriQs AI Expert

UK Electrician · Based on · BS 7671

Online

⚠️ Important: ElectriQs provides information only — not professional electrical advice. Always consult a qualified electrician before any electrical work.

Accept the disclaimer above to start asking questions...

AI-powered · Free · UK electrical only

© 2026 ElectriQs. All rights reserved. A product of Electriman. Terms · Privacy